6. Water tank: Volume size; Carbon steel, stainless steel (combined type) or other type.
7. Ammonia feeding device and dosing device are mainly used to adjust the boiler water index.
"Can shipped on time, not only the ability to schedule Tianjin coal-fired small size 5mw turbine power plant boiler cfb boiler project and the Tianjin Municipal People spend time heating, but also on our fast boiler brand image, so we have to work overtime quality and quantity the coal-fired boiler complete product supply mission. "fast square to official said. Facing short construction period, heavy task difficult, we rationalize production processes, all front-line staff hard working, eventually will be shipped on time to the boiler Tianjin, and running. After the boiler in place, Tianjin coal-fired boiler project also completed the basic preparation, coal-fired boilers, Tianjin is also a blue sky will gradually improve and advance. Tianjin transformation of coal-fired boilers, fast Boiler contributed.
Auxiliary equipment includes gas steam small size 5mw turbine power plant boiler cfb boiler control cabinet, water supply pump, circulating pumps, burners, sub-cylinder, water treatment equipment, energy-saving, condenser and other; each has its high and low points of auxiliary equipment, auxiliary boilers for us do different specifications of configuration options, you can choose the actual needs of appropriate configuration and price.
Gas-fired steam small size 5mw turbine power plant boiler cfb boiler overpressure fault Introduction and approach: 1, boiler overpressure phenomenon of a sharp increase in vapor pressure, exceeds the allowable operating pressure, the safety valve pressure gauge pointer over the red line pressure is still elevated. b. When the interlock operation overpressure protection device, an alarm should be issued overpressure signal to stop the air blowing, the wind, coal. C. steam temperature and steam flow rate reduction increases. 2, boiler overpressure of emergency a. Weakened rapidly burning, manually open the valve or bleed valve. B. to increase the water supply, while the lower reinforcing blowdown drum (It should be noted at this time to maintain the normal water level of the boiler), in order to reduce the temperature of the boiler water, thereby reducing the pressure in the boiler drum. c. If the safety valve pressure gauge malfunction or all of the damage, emergency shutdown, safety valves and pressure gauges are to be repaired after the boost operation. D. When the boiler and endanger the safe operation excessive pressure, blood pressure should take measures, but too fast buck is strictly prohibited. e. When the boiler overpressure eliminate serious, to the shutdown of the boiler internal and external inspection, to eliminate the overpressure caused by deformation, leakage and other safety accessories and repair failed. News / hot water boiler knowledge
Get A Quote